HANABI Automated Lymphocyte Isolator System

The HANABI-L 2.0 Automated Lymphocyte Isolation System is custom designed to radically improve the speed, efficiency and quality of Lymphocytes isolation procedures.
The HANABI-L 2.0 Automated Lymphocyte Isolation System is capable of processing batches of 24 samples and features a negative pressure cabinet and ultraviolet exposure preventing sample contamination.
The HANABI-L 2.0 Automated Lymphocyte Isolation System provides full sample traceability using a novel bar coding feature.

Product Description

ADS Biotec offers the most advanced and state-of -the-art technology in laboratory automation. The HANABI-L 2.0 Automated Lymphocyte Isolation System is designed for today’s laboratories that require increased throughput for higher productivity resulting in consistent, high-quality sample preparation.

The HANABI-L 2.0 Automated Lymphocyte Isolation System simplifies the Lymphocytes’ isolation process from peripheral blood by centrifugation, high definition camera layer recognition and subsequent sample aspiration at controlled temperature, resulting in a truly high-throughput, high-quality procedure. System technology fully automates the entire Lymphocyte isolation process eliminating variability compared to manual methods.

Features and Benefits

• 24 samples walk away capability • Camera reading layer unique feature
• Sterile configuration • Increased laboratory productivity
• Samples traceability • Integral Fume extraction
• Touch screen control panel • Extensive alarm system
• Low maintenance and ease of use • Easy programming capability
NoItemSpecificationsRemarks
1Accepted tube typesBlood collection tube: BD Vacutainer® (Becton, Dickinson
and Co.). Isolating tube: BD Vacutainer® CPT (Becton,
Dickinson and Co.). Storage tube: BD Falcon® 15ml conical
tube (Becton, Dickinson and Co.)
75mm or 100mm height
2Tip typesep T.I.P.S. ® (Eppendorf AG.)
3Throughput capacity1-24 samples
4Sample holderAvailable steam autoclaving
5Centrifuge speed1200-3000 rpmRelative Centrifugal Force:
300-1800xg
6Centrifuge4-20 degrees CSensors for detecting
presence or absence of
sample tubes
7Injection and aspiration
mechanism
Injection volume is adjustable. Tips are replaced per sample
at injection. Shutters included to prevent dropping.
8Stirring methodPipette mixing
9Cell layer identificationUsing camera, lens, capture board, I/O board (trigger
lighting),image processing library
10Sterile inner environmentClean bench (negative pressure inside the equipment, with air
curtain), Ultraviolet exposure, Safety filter (HEPA filter,
Activated charcoal filter)
11Sample ID managementQR code, Data Matrix (ECC200), MicroQR, PDF417, WPC
(JAN/EAN/UPC-A/UPC-E, NW-7, ITF, Code39, Code93,
Code128
12Control systemOn board PC for control of camera, motor, temperature and
sample ID management
13Operating environment15-30 degress, 20-80% RHnon-condensing
14Storage environment0-40 degress C, 0-95% RHnon-condensing, non-icing
15Atmospheric pressure800-1114hPa2000 meters or lower
16Power Input Voltage100-260V (equipped transformer)50/60 Hz
17Power consumptionNot measured
18External Dimensions1400 x 2000 x 1200 (W x H x D)Without door knob and
switches
19WeightNot measured

Warranty

Click here for the pdf version of the warranty.

The HANABI-L 2.0 Automated Lymphocyte Isolator System is warranted to be free from defects in material and workmanship for twelve months following installation, or fourteen months following shipment, whichever occurs first.

The HANABI-L 2.0 Automated Lymphocyte Isolator System Warranty includes the following benefits:

  • One annual preventative maintenance visit at no additional charge.
  • Emergency service visits as required to address operational failures.
  • Replacement parts provided at no charge (excludes consumables and routine replacement parts such as lamps, bottles, filters, PTFE tubing and couplers).
  • Travel and labor expenses associated with preventative maintenance and emergency visits are included.
  • Telephone Hotline Support.

Excluded are no charge replacement parts, travel and labor costs if there is fault or negligence by the customer through misuse or accident. Also excluded are chemistry, consumables and applications issues.

Warranty Terms

Products are supplied for research use only. ADS BIOTEC warrants the Products are free from defects in material and manufacture and conform to ADS BIOTEC’s specifications at the time of shipment. Subject to verification by ADS BIOTEC, if any Product fails to conform to the specifications or any defect in material or manufacture appears: 1) for Products which are scientific instruments within one (1) year from the date of installation; and 2) for related Consumable Products, modules and parts within 30 days from the date of shipment, ADS BIOTEC’s entire liability and Customer’s exclusive remedy shall be, at ADS BIOTEC’s sole discretion, the repair or replacement of the defective Products.

Limitations to Warranty

Unless a separate service plan is purchased, all regularly scheduled maintenance and repairs during the Warranty term shall be the responsibility of Customer. This warranty does not cover any damage to Products due to misuse, improper site selection, and maintenance or operation by Customer or any others which is contrary to recommended instructions and design parameters for the Products. This warranty does not cover damage or defects resulting from repair or relocation of the Products by anyone other than a ADS BIOTEC representative. After the initial installation of the Products any post installation realignment, readjustment, recleaning, or recalibration, unless due to defects in material or workmanship, are the responsibility of Customer. Certain items which are refurbished or otherwise reconditioned are also excluded from the terms of this warranty. This warranty does not cover any damage due to accidents, vandalism, fire, flood, other environmental factors or any other Force Majeure. If you have questions regarding warranty coverage, please contact ADS BIOTEC Customer Service.

The warranty further excludes items supplied by third party manufacturers, such as computers and related software. Customer is responsible for any modifications to the computers or software including, but not limited to: interfacing or networking; unauthorized hardware modifications; repartitioning or reformatting of the hard drive; installation or modification of additional or new hardware; and installation or reinstallation of new or existing computer operating systems or service packs.

THIS WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE; ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING OR OF PERFORMANCE, CUSTOM OR USAGE OF TRADE; OR ANY IMPLIED WARRANTY AGAINST PATENT INFRINGEMENT. UNDER NO CIRCUMSTANCES SHALL ADS BIOTEC BE LIABLE FOR DAMAGES OF ANY KIND, INCLUDING WITHOUT LIMITATION, DIRECT, INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, REVENUE OR BUSINESS) RESULTING FROM OR IN ANY WAY RELATED TO THE PRODUCTS. These limitations apply regardless of whether such damages are sought based on breach of contract, negligence, strict liability in tort, or any other legal theory. The liability of ADS BIOTEC relating to any order by Customer shall in no event exceed the total amount of the payments received by ADS BIOTEC relating to such order. Without regard to any applicable statute of limitations, Customer agrees that any legal action related to any order must be commenced within ninety (90) days of the purchase date.

By placing their order, Customers represent and warrant that they and their employees and agents shall comply with all applicable laws, ordinances, regulations and codes in handling, storage and use of Products and shall indemnify and hold harmless ADS BIOTEC from any claims, rights or causes of action related thereto, or to Customer’s failure act in accord with
these terms and warranties.

To the best of its information and belief, ADS BIOTEC has the necessary intellectual property rights to make the Products. Please contact the ADS BIOTEC Law Department at 7409 Irvington Road, Omaha, NE 68122 with any specific questions. While information and data presented are accurate and reliable to the best of ADS BIOTEC’s information and belief, ADS BIOTEC does not guarantee the accuracy of any information and data, nor do we represent that reliance upon such information and data will ensure the compliance with any applicable laws and regulations.

Product DescriptionCatalog Number
HANABI-L 2.0 Automated Lymphocyte Automated System (US)HALA-99-1020-A
HANABI-L 2.0 Automated Lymphocyte Automated System (EU) HALA-99-1020-B

Hanabi-L 2.0 Sales Flyer – (US)
Hanabi-L 2.0 Sales Flyer – (EU)