HANABI-PI Metaphase Chromosome Harvester

The HANABI-PI is specifically created for small to mid-size throughput, enables processing of up to 16 suspension cultures per run and eliminates variability compared to manual processing methods.

Walk away reliability and low maintenance reduce FTE time associated with the manual harvesting process up to 75%.

Product Description

ADS Biotec offers the most advanced and state-of -the-art technology in cytogenetics automation. The HANABI-PI Metaphase Chromosome Harvester is designed for today’s cytogenetic laboratories System that require increased productivity and throughput with the consistent, professional quality you demand every time.

The HANABI-PI benchmark technology fully automates the multi-step process of preparing and harvesting metaphase cells derived from blood and bone marrow cell cultures and from other cell suspension cultures for cytogenetic analysis.

Features and Benefits
-Increased Laboratory Productivity
-16 sample walk-away harvesting capability
– Automated sample processing: Centrifugation, Vortexing, Aspiration, Injection
-Highly consistent results
-Touch screen control panel
-6 adjustable harvesting protocols
-Low maintenance and ease of use
-Additional features available

ItemsSpecificationsRemarks
Centrifugal tube15mLFalcon (Polypropylene)
Culture cell suspensions10mL (Max)Typical 5mL
Number of samples16 samples4,8,12,16
Total Processing Time1.5hrs (Approx..)16 samples (30 min Hypotonic)
Centrifuge G320 xg (Approx.)1400rpm (r=17cm), Max=1500rpm
Injection pumps2 (0.1mL/rev)PBS/Hypotonic x1: 0.1mL-10mL (+/- 3%)
Fixative x1: 0.1mL-6mL (+/- 3%)
Aspiration pumps4Twin pump x2
Hypotonic treatment temperature37ºCPreheating, Select ON/OFF
Centrifuge section temperature37ºCAir bath, Select ON/OFF
Stirrer (vortex type) Orbital6mmStirring speed 0-2100 rpm
Stirring speed selection2Default: SC1=1500, SC2= 2100 rpm
Protocol selection6A, B, C, D, E, F
Operating environment15-30ºC, 20-60% relative humidityNon-condensing
Storage Temperature0-40ºC, 0-95% relative humidityNon-condensing, Non-icing
Atmospheric pressure800-1114hPa2,000 meters or lower
Pollution degree2Non-conductive levels
Input voltage100, 120, 230 VACVoltage and 50/60 Hz require order specification
Power Consumption800W
External Size mm (W x H x D)850 x 1,600 x 700Without reagent bottles mount and safety filer
Weight250 kg (Approx.)
Safety FilterHEPA + Carbon Filter European version only
Safety StandardsCE Marked
Protocol Data ReadingUSBOptional