HANABI-PII Plus Metaphase Chromosome Harvester

The HANABI-PII Plus reduces hands-on time of the entire harvesting process by 75% allowing time for other specialized tasks, providing increased throughput for your laboratory. Capable of processing up to 24 samples per run eliminates variability compared to manual processing methods.

The HANABI-PII Plus can be integrated with additional options such as reagent sensors, waste fluid tank sensors, extra fixative line, and the HANABI-SPI (auto fixative mixer).

Product Description

ADS Biotec offers the most advanced and state-of -the-art technology in cytogenetics automation. The HANABI-PII Plus Metaphase Chromosome Harvester is designed for today’s cytogenetic laboratories System that require increased productivity and throughput with the consistent, professional quality you demand every time.

The HANABI-PII Plus benchmark technology fully automates the multi-step process of preparing and harvesting metaphase cells derived from blood and bone marrow cell cultures and from other cell suspension cultures for cytogenetic analysis.

Features and Benefits
-Increased Laboratory Productivity
-24 sample walk-away harvesting capability
– Automated sample processing: Centrifugation, Vortexing, Aspiration, Injection
-Highly consistent results
-Touch screen control panel
-6 adjustable harvesting protocols
-Low maintenance and ease of use
-Additional features available

ItemsSpecificationsRemarks
Centrifugal tube15mLFalcon (Polypropylene)
Culture cell suspensions10mL (Max)Typical 5mL
Number of samples24 samples4,8,12,16,20,24
Total Processing Time2.0hrs (Approx..)24 samples (30 min Hypotonic)
Centrifuge G320 xg (Approx.)1200rpm (r=17cm), Max=1500rpm
Injection pumps2 (0.1mL/rev)PBS/Hypotonic x1: 0.1mL-10mL (+/- 3%)
Fixative x1: 0.1mL-6mL (+/- 3%)
Aspiration pumps4Twin pump x2
Hypotonic treatment temperature37ºCPreheating, Select ON/OFF
Centrifuge section temperature37ºCAir bath, Select ON/OFF
Stirrer (vortex type) Orbital6mmStirring speed 0-2100 rpm
Stirring speed selection2Default: SC1=1500, SC2= 2100 rpm
Protocol selection6A, B, C, D, E, F
Operating environment15-30ºC, 20-60% relative humidityNon-condensing
Storage Temperature0-40ºC, 0-95% relative humidityNon-condensing, Non-icing
Atmospheric pressure800-1114hPa2,000 meters or lower
Pollution degree2Non-conductive levels
Input voltage100, 120, 230 VACVoltage and 50/60 Hz require order specification
Power Consumption800W
External Size mm (W x H x D)850 x 1,600 x 750Without reagent bottles mount and safety filer
Weight300 kg (Approx.)
Safety FilterHEPA + Carbon Filter European version only
Safety StandardsCE Marked