WAVE® Nucleic Acid Fragment Analysis System Model 3500-R

Refurbished – subject to availability. Complete System Includes: (1) Degasser, (1) HPLC Pump and Low-pressure Gradient System, (1) Dual Plate Autosampler, (1) 2×96 well tray, (1) L7310T Cartridge Oven, (1) UV Detector, (1) Computer Work Station w/ Navigator Software, and (1) DNASep Cartridge

Contact US

SKU: NAV-99-3500-AR/BR Category:

Product Description

ADS BIOTEC WAVE® 3500 System is offered only as a refurbished system and is subject to availability. A refurbished WAVE® 3500 System meets the same quality standards as all new ADS BIOTEC systems and are backed by the same warranty coverage.

The WAVE® System 3500 is among the most sensitive, accurate, versatile and economical technologies for rapid analysis of SNPs (Single Nucleotide Polymorphisms), and insertion or deletion mutations. The WAVE® System uses denaturing high performance liquid chromatography and may be used in applications for detecting genetic variation and fragment sizing. The Model 3500 meets the requirements of laboratories which are screening hundreds of samples for genetic variation per day.

The WAVE® System 3500 series of DHPLC instruments are offered only as a refurbished systems and are subject to availability. A refurbished WAVE® 3500 System meets the same quality standards as all new ADS BIOTEC systems and are backed by the same warranty coverage.
WAVESystem3500-500x241

The WAVE® System 3500 is among the most sensitive, accurate, versatile and economical technologies for rapid analysis of SNPs (Single Nucleotide Polymorphisms), and insertion or deletion mutations. The WAVE® System 3500 uses denaturing high performance liquid chromatography and may be used in applications for detecting genetic variation and fragment sizing.

Software

Navigator™ Software

  • Internet connectivity for retrieval of genetic sequences
  • Automated prediction of melt temperatures
  • Complete system operating parameters
  • Data analysis and automated mutation calling
  • Network capabilities
  • Separation Cartridge

    DNASep® Cartridge

    • Injection capacity: 0.5 ng to 2 µg
    Computer SystemIntel® Pentium® 4 Processor
    • 512 MB Memory
    • 40 GB Hard Drive
    • CD-RW Drive
    • Microsoft® Windows® 2000 Professional
    • Microsoft® Office®
    Sample Delivery SystemQuaternary Gradient Solvent Delivery System
    • Delivers up to four separate buffers
    • Flow rate control: 0.1 - 1.5 ml/min
    • Flow rate accuracy: ± 2% (H2O at 20 °C)
    AutosamplerWAVE Autosampler Model 7250

    Dual plate:

    • 2 x 96 Samples (standard)

    Temperature control: Factory present 14 °C ± 1 °C
    adjustable 4 ± 0.1 °C
    Sample volume: 200 µL max.
    Injection volume: 1 - 50 µL

    OvenWAVE System 3500 Cartridge Oven Model L-7310T
    • Temperature range: ambient to 40 °C to 100 ºC
    • Temperature precision: 0.1 ºC  increments over entire temperature range
    • Reproducibility: ± 0.1 °C
    • Linearity over full temperature range: ± 0.1 °C
    • Heat and cool rate: Better than 1°C/min

    Detector

    UV/Vis

    • Wavelength range: 190-700 nm
    • UV Source: Deuterium lamp

    Printer

    HP Deskjet 3820 Professional (Required Option)
    HP DeskJet 990CSE Professional (Upgrade)

    Dimensions

    142cm W x 64 cm D x 69 cm H
    (56" W x 25" D x 27" H)
    Weight: 80 kg (180 lb)

    WAVE® System Support Plans

    ADS BIOTEC provides a wide range of WAVE® Customer Support Plans to allow you to experience the maximum benefit from your ADS BIOTEC WAVE® System. WAVE® Customer Support Plans provide different levels of maintenance, support and training allowing you to select what is required for your laboratory. Whether you are a low, medium or high throughput laboratory, we have a support plan to meet your needs.

    WAVE® System Warranty

    ADS BIOTEC WAVE® Systems are warranted to be free from defects in material and workmanship for twelve months following installation, or fourteen months following shipment, whichever occurs first.

    Coverage Summary

    Preventative maintenance visit.
    Emergency visits to address operational failures including parts, labor, and travel expenses at no charge.
    Telephone Hotline Support.
    Software revisions.
    ADS BIOTEC does not replace parts under a no-charge order if there is fault or negligence by the customer through missuse or accident.
    The following items are not covered: operator error, chemistry or application issues, spare parts, post installation training, optional accessories or their installation, and IQ/OQ/PQ services.

    Warranty Terms

    Products are supplied for research use only. ADS BIOTEC warrants the Products are free from defects in material and manufacture and conform to ADS BIOTEC’s specifications at the time of shipment. Subject to verification by ADS BIOTEC, if any Product fails to conform to the specifications or any defect in material or manufacture appears: 1) for Products which are scientific instruments within one (1) year from the date of installation; and 2) for related Consumable Products, modules and parts within 30 days from the date of shipment, ADS BIOTEC’s entire liability and Customer’s exclusive remedy shall be, at ADS BIOTEC’s sole discretion, the repair or replacement of the defective Products.

    Limitations to Warranty

    Unless a separate service plan is purchased, all regularly scheduled maintenance and repairs during the Warranty term shall be the responsibility of Customer. This warranty does not cover any damage to Products due to misuse, improper site selection, and maintenance or operation by Customer or any others which is contrary to recommended instructions and design parameters for the Products. This warranty does not cover damage or defects resulting from repair or relocation of the Products by anyone other than a ADS BIOTEC representative. After the initial installation of the Products any post installation realignment, readjustment, recleaning, or recalibration, unless due to defects in material or workmanship, are the responsibility of Customer. Certain items which are refurbished or otherwise reconditioned are also excluded from the terms of this warranty. This warranty does not cover any damage due to accidents, vandalism, fire, flood, other environmental factors or any other Force Majeure. If you have questions regarding warranty coverage, please contact ADS BIOTEC Customer Service.

    The warranty further excludes items supplied by third party manufacturers, such as computers and related software. Customer is responsible for any modifications to the computers or software including, but not limited to: interfacing or networking; unauthorized hardware modifications; repartitioning or reformatting of the hard drive; installation or modification of additional or new hardware; and installation or reinstallation of new or existing computer operating systems or service packs.

    THIS WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE; ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING OR OF PERFORMANCE, CUSTOM OR USAGE OF TRADE; OR ANY IMPLIED WARRANTY AGAINST PATENT INFRINGEMENT. UNDER NO CIRCUMSTANCES SHALL TRANSGENOMIC BE LIABLE FOR DAMAGES OF ANY KIND, INCLUDING WITHOUT LIMITATION, DIRECT, INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, REVENUE OR BUSINESS) RESULTING FROM OR IN ANY WAY RELATED TO THE PRODUCTS. These limitations apply regardless of whether such damages are sought based on breach of contract, negligence, strict liability in tort, or any other legal theory. The liability of ADS BIOTEC relating to any order by Customer shall in no event exceed the total amount of the payments received by ADS BIOTEC relating to such order. Without regard to any applicable statute of limitations, Customer agrees that any legal action related to any order must be commenced within ninety (90) days of the purchase date.

    By placing their order, Customers represent and warrant that they and their employees and agents shall comply with all applicable laws, ordinances, regulations and codes in handling, storage and use of Products and shall indemnify and hold harmless ADS BIOTEC from any claims, rights or causes of action related thereto, or to Customer’s failure act in accord with these terms and warranties.

    To the best of its information and belief, ADS BIOTEC has the necessary intellectual property rights to make the Products. Please contact the ADS BIOTEC Law Department at 7409 Irvington Road, Omaha, NE 68122 with any specific questions. While information and data presented are accurate and reliable to the best of ADS BIOTEC’s information and belief, ADS BIOTEC does not guarantee the accuracy of any information and data, nor do we represent that reliance upon such information and data will ensure compliance with any applicable laws and regulations.

    ADS BIOTEC reserves the right to alter these terms and conditions at any time and without notice to Customer. Any variance of these terms is not valid unless it is in writing and signed by an officer or other authorized representative of ADS BIOTEC. If you have questions regarding your warranty coverage, please contact ADS BIOTEC Customer Service.

    The FCW 210 WAVE® Fragment Collector may be added to the WAVE® System Model 4500 HT-HS to extend its capabilities.
     

    FCW 210 WAVE® Fragment Collector
    FCW210

    The ADS BIOTEC WAVE® Fragment Collector Model FCW 210 enables fully automated purification of nucleic acids with the WAVE® System. Nucleic acid samples collected by the FCW 210 meet high purity and sample concentration requirements for use in molecular genetic analyses and genomics. The dual plate FCW 210 enables fully automated fractionation and purification of ss- and dsDNA, RNA, and synthetic oligonucleotides with minimum sample loss and minimum cross contamination.

    The FCW 210 is controlled by Navigator™ Software which enables collection of nucleic acid fragments including:

    • Minimum detection threshold above baseline with proprietary baseline drift compensation
    • Time/eluant volume window around peak retention time
    • User-defined collection time windows

    Design refinements in the FCW 210 include a proprietary flow drop control system that delivers:

    • Minimum sample loss
    • Minimum cross contamination
    • Precise drop volume control
    • Maximum sample concentration

    The WAVE® System with the optional Fragment Collector FCW 210 is a robust reliable system for the fractionation and purification of ss- and ds-DNA, RNA and synthetic oligonucleotides.

    An additional feature of the FCW 210 is the ability to chill plates (10 + 2 ºC).

     

    WAVE® 3500 SYSTEMS’ OPTIONAL ACCESSORY MODULES & UPGRADES
    Catalog Number Name Description
    470844 Fragment Collector Shelf Shelf with Four Legs Designed to Support the Fragment Collector with Space Below for Other Items
    FCW-99-0001-AR/BR Fragment Collector FCW-200 Refurbished – subject to availability. Fully Automated Purification of Nucleic Acids with the WAVE® Nucleic Acid Fragment Analysis Systems. Collected samples are of high purity and meet requirements for use in downstream molecular genetic analysis and genomic studies. Collection plates are chilled to prevent evaporation. (Not for use with the WAVE® MD System)
    FCW-99-0210 Fragment Collector FCW-210 Fully Automated Purification of Nucleic Acids with the WAVE® Nucleic Acid Fragment Analysis Systems. Collected samples are of high purity and meet requirements for use in downstream molecular genetic analysis and genomic studies. Collection plates are chilled to prevent evaporation. Note: Requires item 332014 to function in a 4500 series system. (Not for use with the WAVE® MD System)
    WAVE® 3500 SYSTEMS’ OPTIONAL ACCESSORY MODULES
    Catalog Number Name Description
    HSD-99-0002-AR/BR WAVE® HSD High Sensitivity Detector (3500 Series) Refurbished – subject to availability. Incorporates Fluorescence Detection and Intercalation Chemistries to Provide Sensitivity Enhancements for the Detection of ds- and ss- DNA and RNA without Fluorescently Labeled Primers. WAVE® HSD consists of: • WAVE® FDX – Fluorescence Detector Wavelength range: lex, 200-850 nm; lem, 250-900 nm Fluorescence source: 150 W Xenon lamp • WAVE® HSX – High Sensitivity Accessory • Requires Navigator Software (not included)
    HSX-99-0002-AR/BR High Sensitivity Accessory (3500 series) Refurbished – subject to availability. Module to be combined with the FDX Fluorescence Detector to form the High Sensitivity Detection System
    WAVE® SYSTEM UPGRADES – 3500 SERIES
    Catalog Number Name Description
    UP1003 Upgrade from 3500 to 3500HT Refurbished – subject to availability. Upgrade a 3500 system to a 3500HT system, includes Rapid Analysis package and Internal Accelerator; must have dual plate autosampler
    UP1008 Upgrade of Internal Accelerator from 3500 to 3500A Internal Accelerator Only; must have a dual plate autosampler
    UP1011 Upgrade from 3500A to 3500HT Rapid Analysis package; does not include internal accelerator
    UP1027 L7320T Turbo Oven L7320T Turbo Oven – Upgrade for WAVE® 3500 Models; must have Navigator Software
    UP1028 L7320T Turbo Oven plus Navigator/Computer L7320T Turbo Oven and Navigator Software plus Navigator-compatible Computer
    UP1028 L7320T Turbo Oven plus Navigator/Computer L7320T Turbo Oven and Navigator Software plus Navigator-compatible Computer
    Navigator SOFTWARE
    Catalog Number Name Description
    NAV-99-1000 Navigator System, Including Workstation New Workstation, Navigator software, Oracle, GPIB, Network card, Installation and Orientation
    NAV-99-2000 Navigator Software, Field Installed Includes Navigator Software, Installation and Orientation. It requires the customer to have the appropriate CPU.
    NAV-99-4000 Navigator User Expansion Pack, Optional Provides the ability to add five additional licensed users to the Navigator system. User installable.
    WAVE® SYSTEM SUPPORT PLANS
    Catalog Number Name Description
    LABOR Service Labor, non contract On site service provided for customers not covered by a service contract. Four hour minimum plus travel expenses.
    SER-MD.COM-IYR Premium Access to MutationDiscovery.com® (per year) Premium Access to MutationDiscovery.com provided for 1 year. Includes ability to design and store amplicons, DHPLC methods, and results.
    SER-PLN Basic Service Plan A one year instrument support plan that includes one preventative maintenance visit per year.
    SER-PM3500 Preventative Maintenance Visit – WAVE® 3500 System Preventative maintenance visit on WAVE® 3500 System includes one day of labor, 1 x SP2018 and 1 x 540088. Travel costs are not included.
    SER-PRE Premier Support Plan A one year instrument support plan that includes two preventative maintenance visits per year.
    SER-PRE-HT HT Premier Support Plan A one year instrument support plan for high throughput labs that includes three preventative maintenance visits per year.
    TRAINING Product Training Training for any product, operator or applications performed at a customer lab site. Four hour minimum plus travel expenses.
    Pump Parts
    Catalog Number Name Description
    280239 4 Port Inlet Valve 4 port inlet valve for pump head one
    300193 Pump Suction Valve Tubing Larger ID tubing and fitting for Low Pressure Gradient; (connects to degasser); solenoid end fitting/ferrule included
    300196 Drain Tubing for Purge Waste tubing for drain/purge valve on pump
    470821 Flow Path Filter (UHMW PE) PEEK flow path filter with UHMW PE frit for 3500 systems and drain valve of 4500 systems
    472044 Low Volume Mixer Low volume mixer for 3500HT and all 4500 models
    500064 Solenoid Valve Single solenoid valve replacement for the L-7100 pump.
    500067 Drain Valve Seal Black Seal for the drain (purge) valve on the L-7100 pump
    500072 Valve Packing 4-way  
    500096 Check Valve Outlet PEEK outlet (top) check valve for the L-7100 pump
    500097 Check Valve Cartridge Kit (for optimized check valves only) Set of 2 PEEK check valves for L7-100 pump – compatible with the optimized check valves only.
    500098 Check Valve Inlet PEEK inlet (bottom) check valve for L-7100 pump
    540085 Plugs for Suction Valve Plugs for the 4-way inlet valve on the pump
    540086 Plunger Plunger for the L7100 or L2130 pump
    540089 Drain Valve Filter Packing White drain (purge) valve filter packing for the pump
    540090 Plunger Guide Plunger guide for the L-7100 or L2130 pump
    540091 Priming Syringe Plastic syringe and fitting for priming the pump
    542000 Standard Volume Static Mixer Standard Volume (750 µL) mixer for L7100 for non-HT 3500 systems
    542001 Piston Seal, UHMW PE Single pump seal. Order 2 of this Catalog Number for a complete set
    Autosampler Parts
    Catalog Number Name Description
    210264 Hex Head Screws 30 mm for Diluter Valve Replacement screw for phillips head diluter valve screws. Order 2 of this Catalog Number and 2 of Catalog Number 210265 for a complete set.
    210265 Hex Head Screws 16mm for Diluter Valve Replacement screw for Phillips head diluter valve screws. Order 2 of this Catalog Number and 2 of Catalog Number 210264 for a complete set.
    210269 Thumbscrew for Autosampler Side Panel Thumbscrew for side panel for L-7200 and L-7250 autosamplers
    300194 Connection tube (needle to syringe) 500 µL tubing for needle to syringe connection
    300195 Sample Loop 100 µL 100 µL stainless steel sample loop for L-7200 or L-7250 autosampler
    300197 Drain tubing for Waste Large white waste tubing for the autosampler
    300198 Sample Loop 20 µL 20 µL stainless steel loop for the L-7200 or L-7250 autosampler
    300199 Sample Loop 10 µL 10 µL stainless steel loop for the L-7200 or L-7250 autosampler
    302005 Sample Loop 500 µL, Stainless Steel 500 µL stainless steel sample loop for the autosampler
    302006 Sample Loop 500 µL, PEEK 500 µL PEEK sample loop for the autosampler
    382048 Sample Holder, 96 Well 96 well autosampler plate
    382050 Sample Holder, 384 Well 384 well autosampler plate
    390453 Sample Tray, Oligo, 120 position 120 position sample tray for the WAVE® Oligo System
    390454 Sample Tray Holder, Oligo, 2×96 position 2 x 96 position deep well tray holder for the WAVE® Oligo System
    442025 Syringe Feed Line with Fittings Tubing leading from degasser to syringe (fitting/ferrule included)
    450205 Needle Needle for the L-7200 and L-7250 autosampler
    450207 Needle sleeve Needle sleeve for L-7200 and L-7250 autosampler
    450251 Diluter Spring Support Bearing Spring support bearing for the syringe valve on the L-7200 or L-7250
    450286 Syringe, 100µL 100 µL syringe plus syringe-needle tubing for the L-7200 or L-7250
    450324 Injection Port Transfer Tubing Stainless steel tubing from injection port to injection valve for L-7200
    450327 Sample Tray Holder, DNA, 2×96 position Sample tray holder, 2×96 positions, for all L-7250 autosamplers except for those in Oligo Systems
    450328 Syringe Kit, 5 mL Syringe kit for the L-7250 Autosampler
    450332 Syringe Kit, 2.5 mL for L-7250 2.5 mL syringe plus syringe-needle tubing for L-7250 Autosampler
    450334 Sample Loop, 2 mL, PEEK, for L-7250 2 mL PEEK sample loop for the L-7250 autosampler
    500068 Injection Port Seal Injection port seal for the L-7200 or L-7250 autosampler
    500070 Diluter Valve Seal Diluter (or syringe) valve seal for the L-7200 or L-7250 autosampler
    500073 Injection Valve Injection valve for the L-7200 or L-7250 autosampler
    540084 Diluter Valve Stator Diluter (or syringe) valve stator for the L-7200 or L-7250 autosampler
    540088 Syringe 0.5 mL 500 µL syringe for the autosampler
    540117 Isolation Seal Isolation seal for L-7200 or L-7250
    540118 Rotor Seal, Injection Valve Rotor seal for the injection valve on the L-7200 or L-7250 autosampler
    540119 Rebuild Kit – Rheodyne Includes rotor seal & isolation seal with tools for the L7200 or L7250 injection valve
    540120 Rebuild Kit with Stator Includes rotor, isolation seals and stator for the L7200 or L7250 injection valve
    540123 Injection Valve stator Injection valve stator for L7200 or L7250 Autosampler
    Oven Parts
    Catalog Number Name Description
    302020 Preheat Coil, Polyimide PEEK, 2 m Polyimide PEEK preheat coil for L-7300 series oven, 2 meters
    302054 Preheat Coil, Polyimide PEEK, 2 m Polyimide PEEK preheat coil for L-7310T series oven, 2 meters
    530011 Inline Filter, PEEK, 0.5 µm 0.5 µm inline filter (located prior to preheat coil in oven)
    530016 Filter End Fitting, PEEK 0.5 µm fitting for the inline filter
    UV Detector Parts
    Catalog Number Name Description
    070024 Deuterium Lamp, 1000 hours Standard lamp for UV detector for 1000 hours
    302028 Flowcell Tubing Modification Kit Polyimide inlet tubing (0.8 m, 0.008″ ID) and PEEK outlet tubing (0.98 m, 0.01″ ID) for the L7400 UV detector flowcell
    450206 Flowcell for UV Detector Standard 10 mm flow cell for L7400 UV detector
    450331 Flow Cell Assembly, 0.5 mm for L-7400 Assembly of flow cell, housing & tubing for the L7400 UV detector for oligo applications
    Fluorescence Detector/HSX Parts
    Catalog Number Name Description
    070030 Xenon Lamp, 150 hours Standard lamp for Fluorescence detector for 150 hours
    070031 Xenon Lamp, Long Life, 500 hours Long life for Fluorescence detector for 500 hours
    450284 Flowcell for Fluorescent Detector Standard flow cell for the L-7480 or L-7485 Fluorescence detector
    502017 Pump Seal Kit Pump seal for the HSX pump
    Miscellaneous Parts
    Catalog Number Name Description
    162013 GPIB Board & Cable GPIB Board and cable for dc7100 and dc7600 computers (see 450179)
    172002 Septa Strips One cover fits a 96-well tray of 0.2 mL tubes
    280092 Tee, 1/4 – 28,.05 hole, PEEK PEEK Tee, 1/4 -28
    280229 Fittings with Ferrule PEEK wing-nut type fittings with unattached ferrule
    280230 Union Black PEEK union
    280248 Fitting, Fingertight, PEEK, 10-32 PEEK fittings with attached ferrules
    282035 Ferrule, PEEK, Natural PEEK ferrule only that goes with wing-nut type fitting
    300126 Tubing PFA Natural .065 id Tubing for detector outlet extension or degasser
    300190 Tubing, PEEK, 0.007″ ID, Yellow PEEK tubing ( 0.007″ ID, yellow), order 3 ft (0.9m) to connect outlet of inline mixer with the Autosampler
    360120 GPIB Cable (2.0 m) Communications cable to connect workstation with D-7000 Interface Module
    360125 D-line Cable (1 m) Standard D-line for WAVE® Systems, 1 meter long
    390412 Fritted Filter, UHMWPE, 0.480  
    392020 Fritted Filter, UHMWPE, 0.344  
    450179 GPIB Board GPIB Board for other computer models (see 162013); cable not included
    530010 Solvent Inlet Filter Inlet filter for buffers
    SP2018 Universal Preventative Maintenance Kit – 3500 Systems Diluter spring support bearing, UMWHPE Filter, drain valve seal, diluter valve seal, valve packing 4-way, drain valve filter packing, rheodyne rebuild kit, injection port seal, pump seals
    SP3500 WAVE® 3500 Systems Service Plan Maintenance Kit Complete maintenance kit for WAVE® 3500 System. Contains 2 x SP2018 and 1 x 540088
    SP5906 PEEK Tubing (5 ft) Yellow PEEK tubing in 5 foot length (1.52 meters)
    SP5917 Polyimide Peek tubing Polyimide PEEK tubing 91 inches (2.3 meters)
    GLASSWARE
    Catalog Number Name Description
    400055 Solvent Bottle, 1 Liter 1 liter glass solvent bottle (clear)
    400056 Volumetric Flask, 250 mL 250 mL glass volumetric flask (clear)
    400057 Volumetric Flask, 1 Liter 1 liter glass volumetric flask (clear)
    400065 Volumetric Flask, 50 mL 50 mL glass volumetric flask (clear)
    400070 Solvent Bottle, 2 Liter 2 liter glass solvent bottle (clear)
    400071 Volumetric Flask, 500 mL 500 mL glass volumetric flask (clear)
    400072 Volumetric Flask, 2 Liter 2 liter glass solvent bottle (clear)
    400073 Volumetric Flask, 100 mL 100 mL glass volumetric flask (clear)

     

    WAVE Premier Support Plan
    WAVE Basic Service Plan
    WAVE Non-contracted Services
    WAVE Applications and Training Plan
    WAVE Preventative Maintenance Visit.
    Separation and Purification of Short Tandem Repeat (STR) DNA Fragments Using Denaturing HPLC (DHPLC)
    Quality Control and Purification of Oligonucleotides on the WAVE Nucleic Acid Fragment Analysis System
    PCR Amplification and Automated Sequencing of DNA Fragments Isolated with the WAVE Nucleic Acid Fragment Analysis System
    Competitive Quantitative PCR on the WAVE Nucleic Acid Fragment Analysis System
    Automated and Rapid Genotyping of Mouse Colonies with the WAVE Nucleic Acid Fragment Analysis System
    Sizing of DNA Fragments with the WAVE Nucleic Acid Fragment Analysis System
    Detection of Mutations in the ATM Gene: Comparison of Denaturing HPLC (DHPLC) with Single Strand Conformation Polymorphism (SSCP)
    Enhancing Core Facility Services with the WAVE Nucleic Acid Analysis System Technology
    Microsatellite DNA Analysis with the WAVE Nucleic Acid Fragment Analysis System
    Superiority of Denaturing High Performance Liquid Chromatography Over SSCP for Mutation Detection in TSC2
    Single Nucleotide Polymorphism (SNP), Insertion; Deletion on the WAVE Nucleic Acid Fragment Analysis System
    Gender Determination by Amelogenin Specific PCR and Product Analysis by DNA Chromatography
    Sequencing of DNA Fragments Isolated with the WAVE Nucleic Acid Fragment Analysis System
    RNA Chromatography Under Thermally Denaturing Conditions: Analysis and Quality Determination of RNA
    RNA Chromatography Under Thermally Denaturing Conditions: Quantitation of RNA
    ADS BIOTEC Optimase Polymerase Delivers Highest Fidelity in PCR for WAVE System Analysis (US)
    WAVE System 3500 Cartridge Oven Module L-7320T